- NO, NC and COM Contacts Flexible switching arrangements for each relay.
- LED Indicators Individual indicators display relay activation status.
- Screw Terminal Connections Convenient connections for power, control signals and external loads.
- Four Mounting Holes Allow secure installation inside project enclosures.
Technical Specifications
Applications
1. Arduino Home Automation
Use the module to control four independent electrical circuits from a single Arduino development board.
For example, the Arduino Uno R3 Development Board can provide digital control signals for operating different relay channels.
2. Smart Home and IoT Projects
Create programmable switching systems for lighting, ventilation, alarms and compatible electrical equipment.
3. Automatic Water Pump Control
Use the relay board as part of a water level monitoring and automatic pump control system, with properly rated external switching equipment where required.
4. Robotics and Automation
Control suitable solenoids, actuators, indicator circuits and other electrical loads from a microcontroller.
5. Timer-Based Switching
Build automatic switching systems that activate or deactivate different devices according to programmed time schedules.
6. STEM and Electrical Education
Demonstrate electromagnetic relays, digital logic, optocoupler circuits, HIGH/LOW trigger selection and multi-channel electrical control.
How the 4-Channel Relay Module Works
Each relay functions as an electrically operated switch.
A microcontroller sends a digital signal to one of the four control inputs. Depending on the corresponding jumper setting, the relay activates when the input becomes HIGH or LOW.
When activated, the relay changes the connection between its Common (COM), Normally Open (NO) and Normally Closed (NC) contacts.
Each channel operates independently, allowing four different circuits to be controlled from one board.
HIGH and LOW Trigger Selection
The module contains four jumper selectors labelled S1, S2, S3 and S4.
Each selector corresponds to one relay channel.
The jumper header provides three positions: LOW, COM and HIGH.
LOW-Level Trigger
Connect the jumper between LOW and COM. The corresponding relay activates when its control input receives a LOW signal.
HIGH-Level Trigger
Connect the jumper between HIGH and COM. The corresponding relay activates when its control input receives a HIGH signal.
All four relays can use the same trigger mode, or each can be configured differently.
Power Supply and Control Connections
A separate power supply may be necessary if the microcontroller cannot supply sufficient current for all four relay coils.
Connecting to Arduino Uno
A typical control connection is:
Configure S1-S4 for the required trigger logic.
Connect the Arduino ground to the module’s control ground and ensure the selected input signal levels are compatible.
For prototyping and convenient connections, DIYGH stocks Male-to-Female Jumper Wires.
Understanding the Relay Output Terminals
Each relay provides three electrical contacts.
- COM (Common) The shared switching terminal.
- NO (Normally Open) Connects to COM when the relay activates.
- NC (Normally Closed) Connects to COM when the relay is inactive.
These connections allow the module to control circuits that should turn ON or OFF when a relay is activated.
The external load circuit is electrically separate from the low-voltage relay control signal.
Selectable Trigger vs Fixed LOW-Level Trigger
The main advantage of this board is its flexible trigger configuration.
The HIGH/LOW selection allows developers to choose the control logic that best suits their programmed application.
For projects requiring only LOW-level triggering, DIYGH also stocks the 4-Channel 5V Relay Module with Fixed LOW-Level Trigger.
For simpler projects requiring just one switching circuit, consider the 1-Channel 5V Relay Module.
Important Usage Information
- Use the supply voltage specified for the actual relay coil version.
- Disconnect power before changing trigger jumpers or terminal wiring.
- Check that the input signal voltage is compatible with the relay module.
- Verify HIGH/LOW triggering before connecting important equipment.
- Optocoupler inputs do not guarantee complete galvanic isolation if the control and relay circuits share a power supply.
- The relay contact ratings do not automatically establish the safe switching limits of the complete module.
- Use suitable protection when switching motors, pumps and other inductive loads.
- Ensure the PCB is securely mounted and protected from accidental contact.
- For mains-powered applications, use a qualified electrician, suitable enclosures, protective devices and properly rated wiring.
Package Includes
- 1 x 4-Channel Relay Module with HIGH/LOW Trigger Selection (5V Version)
Microcontroller, connection wires, external power supply and enclosure are not included.